Generators Help



Search:

Understanding Power Supply Repair Safety

Would you like to
contribute to this site?

Generators Menu

Submit an Article
Submit a Tip
Place your Ad
Add URL
Generators Questions?
Contact Us


 Emergency Power 
 Emergency Generators 
 Backup Power 
 Backup Generators 
 Standby Power 
 Standby Generators 
 Types Of Generators 
 Power Generators 
 Portable Generators 
 Home Generators 
 Industrial Generators 
 Electrical Generators 
 Diesel Generators 
 Types Of Diesel Generators 
 Gas Generators 
 Natural Gas Generators 
 Propane Generators 
 Wind Generators 
 Solar Generators 
 Steam Generators 
 RV Generators 
 Generators By Brand 
 Generac Generators 
 Onan Generators 
 Coleman Generators 
 Yamaha Generators 
 Transfer Switches 
 Generator Transfer Switches 
 Power Supply 
 Generators For Sale 
 Used Generators 
 Generator Rental 
 Generator Information 

Return To Generators Article Archive
 


Understanding Power Supply Repair Safety

By Jestine Yong


It is very important to know the power supply repair safety before you begin to dismantle the equipment. If you accidentally caused a small amount of current to flow through your body, you may get a shock and even death! Always be alert when deals with power supply. Understand how electricity and power supply work can help you to avoid from electrocuted. Always wears a rubber shoe and have an isolation transformer in your technical department or working area. You may find out more information about isolation transformer by searching on the internet.

If you want to check the hot section in a power supply, always use the one hand 'rule' so that it would not complete a path for current to flows through your body just in case if you were to accidentally touched a live connection or cable. If you are tired and weak, do not repair any electronic equipment or else you might end up causing more problems for the equipment by replacing a wrong component. Take a break and come back to tackle the problem when you are fresh again.

Always use original part numbers for replacement when dealing with components in the critical section such as the fuse area. If the fuse rating is 3 ampere, then you must replace it with the same value which is 3 ampere. Sometimes a slightly higher ampere such as 3.15 ampere may be acceptable. Do not use a 10 or 15 ampere for replacements otherwise fire may occurred due to over current because the fuse may not melt.

The main filter capacitor with a high capacitance and voltage must be installed in the correct location. The positive marking at the capacitor must be inserted to the hole where it printed (+) and a negative marking to (-). A wrongly installed filter capacitor can cause the filter capacitor to explode and may injure your face if you are near to it. In some severed cases, the blown capacitor may burn the power supply as well.

Lastly, don't because of this information explained above scared you away from repairing a power supply. Just make sure you understood the power supply repair safety first and things will become easier. Understanding the safety procedure above can protect your life.

Jestine Yong is a electronic repairer and a writer, for more power supply repair tips, please visit his website at http://www.electronicrepairguide.com